Janaury 13, 1975 HO-10 Bulletin No:: Monitor Scope HO-10-1 "Hot" Chassis" Some transformers [PN 54-130] have been found to break down after about five hours of use. The the primary shorts to the high voltage secondary, raising the chassis approximately 1000V above the line voltage. If a new power transformer has been installed, be sure to let the unit operate for a while before returning it to the customer. The vendor has been notified, and corrections will be made in replacement stock -------------------------------------------------------------------------------------------------------------------- October 21, 1980 HO-10 Bulletin No: Monitor Scope HO-10-2 Replacing the Power Transformer + + + + Information not yet available + + + + -------------------------------------------------------------------------------------------------------------------- December 9, 1981 HO-10 Bulletin No: Monitor Scope HO-10-3 Replacing the Power Transformer (Supercedes SB HO-10-2} + + + + Information not yet available + + + + -------------------------------------------------------------------------------------------------------------------- June 24, 1988 HO-10 Bulletin No: Monitor Scope HO-10-4 0.15 uf, 1.6 kV Capacitor [PN 23-94] NLA The .15 uf, 1.6 kV capacitor [PN 23-94] at C30 and C31 are no longer available from Heath Parts Replacement. A .1 uf, 1.6 kV capacitor [PN 23-62] and a 0.047 uf, 1.6 kV capacitor [PN 23-91] is used as a substitute. Connect these two capacitors in parallel with the banded ends in the same direction. --------------------------------------------------------------------------------------------------------------------